Dryer Sizing
To select a dryer for you application, first find the capacity correction factors that correspond to your compressed air pressure and temperature from Table 1 and the ambient air temperature or cooling water temperature from Table 2. Multiply the two factors together to find the overall capacity correction factor. Multiply a dryer's rated capacity by the overall capacity correction factor to determine the dryer's capacity at your operating conditions. Outlet dew point correction factors may be used when the required dewpoint is greater than 38°F.






Specifications

Manufacturer

Product Family

Refrigerated Air Dryers

Series

Demand Manager

Capacity

600 to 3000 scfm

Rated Capacity at 38°F

750 scfm

Rated Capacity at 50°F

975 scfm

Max. Working Pressure

232 psig

Nominal Refrigeration Horsepower

3.0

Available Voltages

208-230V - 3 - 60Hz
380-420V - 3 - 50Hz

460V - 3 - 60Hz

575V - 3 - 60Hz

Connection Size (Inlet/Outlet)

3 in.

Connection Type

NPT

Height

58 in.

Width

28 in.

Depth

65 in.

Weight

734 lbs (Air Cooled)
661 lbs (Water Cooled)