Accessorie Air
Home
Contact Us
Areas Served
Manufacturers
Rentals
Services
Air Compressors
After coolers and dryers
filtration systems and accessories
Paint spray equipment
Search Catalog
By Keyword
By Item #
All Categories
Activated Carbon Tower - Clean Air Treatment
All Categories
>
Filtration Systems and Accessories
>
Compressed Air Filters
>
Activated Carbon Tower - Clean Air Treatment
>
View Items
Activated Carbon Tower - Clean Air Treatment
Check up to five results to perform an action.
larger image
Kaeser's Activated carbon Towers (KAT) are single tower pressure vessels filled with activated carbon adsorbent, that virtually eliminates oil vapor in compressed air. Other hydrocarbon vapors normally absorbable by activated carbon are also removed.
KAT's are used where oil vapor and odor contaminate end products such as food and drugs, or when the odor makes the environment uncomfortable.
Activated carbon works by adsorbing contaminants onto the surface of its internal pores. This process continues until it is saturated. When this occurs, the spent activated carbon should be removed and replaced.
Easy Installation
The KAT only requires piping connection for complete installation. For best performance, the KAT should be installed after a refrigerated air dryer. Using a Kaeser coalescing oil removal filter as a prefilter will greatly extend the life of the carbon bed. A Kaeser particulate filter installed after the KAT will prevent carbon dust and other solid contaminants from going downstream and harming equipment.
Engineering Data
Maximum Inlet Flow Capacities Table 1 lists the maximum inlet flow capacity at 100 psig. To determine maxi mum inlet flows at inlet pressures other than 100 psig, multiply the maximum flow from Table 1 by the multiplier from Table 2 that corresponds to the KAT inlet pressure.
Tower Sizing
At an inlet oil vapor concentration of 0.1 ppm w/w, the adsorber tower has a life of 30,000 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil at 75°F and 100 psig.
At an inlet oil vapor concentration of 0.35 ppm w/w, the adsorber tower has a life of 8,800 hours at rated flow conditions. This concentration corresponds to air saturated with typical mineral oil of 100°F and 100 psig.
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 16 of 16
1
Item #
Max. Flow at 100 psig
Max. Working Pressure
Dimensions (H x W x D)
Connection Size (Inlet/Outlet)
Connection Type (Inlet/Outlet)
Weight
KAT 60
60
scfm
250
psig
70 x 10 x 24
in.
N/A
NPT
68
lbs
KAT 80
80
scfm
250
psig
72 x 11 x 24
in.
N/A
NPT
89
lbs
KAT 120
120
scfm
250
psig
78 x 15 x 16
in.
1
in.
NPT
157
lbs
KAT 190
190
scfm
250
psig
60 x 17 x 18
in.
1 1/2
in.
NPT
176
lbs
KAT 350
350
scfm
200
psig
63 x 20 x 20
in.
1 1/2
in.
NPT
201
lbs
KAT 500
500
scfm
200
psig
64 x 22 x 22
in.
2
in.
NPT
271
lbs
KAT 600
600
scfm
200
psig
69 x 25 x 25
in.
3
in.
NPT
353
lbs
KAT 800
800
scfm
200
psig
70 x 27 x 27
in.
3
in.
NPT
415
lbs
KAT 1000
1000
scfm
200
psig
72 x 29 x 29
in.
4
in.
Flange
474
lbs
KAT 1250
1250
scfm
200
psig
73 x 31 x 31
in.
4
in.
Flange
604
lbs
KAT 1500
1500
scfm
200
psig
73 x 33 x 33
in.
4
in.
Flange
662
lbs
KAT 1800
1800
scfm
180
psig
74 x 36 x 35
in.
4
in.
Flange
741
lbs
KAT 2100
2100
scfm
200
psig
80 x 37 x 37
in.
4
in.
Flange
1136
lbs
KAT 2800
2800
scfm
200
psig
79 x 42 x 42
in.
4
in.
Flange
1279
lbs
KAT 4000
4000
scfm
200
psig
84 x 48 x 59
in.
6
in.
Flange
1840
lbs
KAT 5500
5500
scfm
180
psig
88 x 54 x 65
in.
6
in.
Flange
2578
lbs
Results 1 - 16 of 16