Dryer Sizing
To select a dryer for you application, first find the capacity correction factors that correspond to your compressed air pressure and temperature from Table 1 and the ambient air temperature or cooling water temperature from Table 2. Multiply the two factors together to find the overall capacity correction factor. Multiply a dryer's rated capacity by the overall capacity correction factor to determine the dryer's capacity at your operating conditions. Outlet dew point correction factors may be used when the required dewpoint is greater than 38°F.
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 17 of 17
1
Item #
Series
Rated Capacity at 38°F
Rated Capacity at 50°F
Max. Working Pressure
Connection Size (Inlet/Outlet)
Dimensions (H x W x D)
TF 171E
Demand Manager
600
scfm
780
scfm
232
psig
3
in.
58 x 28 x 65
in.
TF 210E
Demand Manager
750
scfm
975
scfm
232
psig
3
in.
58 x 28 x 65
in.
TG 301E
Demand Manager
1000
scfm
1300
scfm
232
psig
4
in.
85 x 50 x 51
in.
TH 371E
Demand Manager
1300
scfm
1690
scfm
232
psig
4
in.
85 x 50 x 51
in.
TH 451E
Demand Manager
1500
scfm
1950
scfm
232
psig
4
in.
85 x 50 x 51
in.
TI 521E
Demand Manager
1750
scfm
2275
scfm
232
psig
6
in.
85 x 57 x 60
in.
TI 601E
Demand Manager
2000
scfm
2600
scfm
232
psig
6
in.
85 x 57 x 60
in.
TI 751E
Demand Manager
2500
scfm
3250
scfm
232
psig
6
in.
85 x 57 x 60
in.
TI 901E
Demand Manager
3000
scfm
3900
scfm
232
psig
6
in.
85 x 57 x 60
in.
TG 241
Dual Control
800
scfm
1040
scfm
232
psig
3
in.
85 x 49 x 41
in.
TG 301
Dual Control
1000
scfm
1300
scfm
232
psig
3
in.
85 x 49 x 41
in.
TH 371
Dual Control
1300
scfm
1690
scfm
232
psig
4
in.
85 x 49 x 41
in.
TH 451
Dual Control
1500
scfm
1950
scfm
232
psig
4
in.
85 x 49 x 41
in.
TI 521
Dual Control
1750
scfm
2275
scfm
232
psig
6
in.
85 x 59 x 59
in.
TI 601
Dual Control
2000
scfm
2600
scfm
232
psig
6
in.
85 x 59 x 59
in.
TI 751
Dual Control
2500
scfm
3250
scfm
232
psig
6
in.
85 x 59 x 59
in.
TI 901
Dual Control
3000
scfm
3900
scfm
232
psig
6
in.
85 x 59 x 59
in.
Results 1 - 17 of 17